beautypg.com

HP StorageWorks 2.140 Director Switch User Manual

Page 256

background image

Information and Error Messages

254

Error Messages

Port cannot swap to

itself.

Port addresses entered

in the Swap Ports

dialog box are the

same.

Ensure that address in the first

and second Port Address fields

are different.

Port diagnostics

cannot be performed

on an inactive port.

This displays when

port diagnostics is run

on a port in an

inactive state.

Run the diagnostics on an

active port.

Port speeds cannot be

configured at a higher

rate than the director

speed.

This displays when you

configure a port to 2

Gb/sec and the

director speed is set to

1 Gb/sec.

Set the director speed to 2

Gb/sec in the Configure Switch

Parameter dialog box.

Port numbers must be

in the range of 0 to

xxx.

When configuring

Preferred Paths, source

ports and exit ports

must be in the range of

ports for the switch

being configured.

In the Configure Preferred

Paths dialog box, change the

numbers in the Source Port and

Exit Port fields to fall within the

port count of the switch on

which you are configuring

paths.

Preferred Paths can

not be enabled until

the Domain ID is set to

Insistent. Disable

Preferred Paths, then

configure Switch

Parameters.

If the switch’s domain

ID has not been set to

Insistent, the user is not

allowed to activate the

Preferred Path

configuration with the

Enable Preferred Paths

check box selected.

Close the Configure Preferred

Paths dialog box and click

Configure > Operating

Parameters > Switch

Parameters. In the Configure

Switch Parameters dialog box,

click the Insistent check box.

R_A_TOV must be

greater than

E_D_TOV.

R_A_TOV must be

greater than

E_D_TOV.

Change one of the values so

that R_A_TOV is greater than

E_D_TOV

Resource is

unavailable.

The specified

operation cannot be

performed because the

product is unavailable.

Verify that the Ethernet

connection between the HAFM

appliance and the director is

up or available.

Resource is

unavailable.

The specified

operation cannot be

performed because the

product is unavailable.

Verify that the HAFM

appliance-to-product link is up.

If the link is up, the HAFM

appliance may be busy. Try the

operation again later.

Table 10: Element Manager Messages (Continued)

Message

Description

Action

This manual is related to the following products: