Using Logs

172

Director Element Manager User Guide

Severity—There are four classifications of severity that identify the
importance of the event.

— 0=Informational

— 2=Minor

— 3=Major

— 4=Severe (not operational)

FRU Position—An acronym representing the FRU type, followed by a
number representing the FRU chassis position. FRU acronyms are:

BKPLNE—backplane

CTP—CTP card

SBAR—SBAR card

Port—card

FAN—fan module

PWR—power supply

The chassis (slot) position for a non-redundant FRU is 0. The chassis
positions for redundant FRUs are 0, 1, and 2. The chassis positions for port
cards are 0 through 35, and slot 32 is unavailable.

Event Data—Up to 32 bytes of supplementary information for the event in
hexadecimal format. For detailed information on event data and problem
resolution, refer to the event code tables appendix in the HP StorageWorks
Director 2/64 Service Guide
for the Director 2/64 and the HP StorageWorks
Director 2/140 Service Guide
for the Director 2/140.