beautypg.com

HP StorageWorks 2.140 Director Switch User Manual

Page 251

background image

Information and Error Messages

249

Director Element Manager User Guide

Invalid response

received from director.

An error occurred at

the director during a

firmware download

operation.

Retry the firmware download

operation. If the problem

persists, contact the next level

of support.

Invalid serial number

for this feature key.

The serial number and

the feature key did not

match.

Ensure that the feature key

being installed is specifically

for this director serial number.

Invalid UDP port

number.

The specified user

datagram protocol

(UDP) port number is

invalid. The number

must be an integer

from 1 through 65535

inclusive.

Verify and enter a valid UDP

port number from 1 through

655535.

Invalid value for

BB_Credit.

At the Configure

Fabric Parameters

dialog box, the

buffer-to-buffer credit

(BB_Credit) value must

be an integer from 1

through 60 inclusive.

Verify and enter a valid

number between 1 through 60.

Invalid value for Low

BB Credit threshold

(1-99) %.

Low BB Credit

Threshold field in

Configure Open

Trunking dialog box

must have entries in

the range from 1 and

99. This message only

displays if the optional

Open Trunking feature

is installed.

Enter a value from 1 to 99 into

the Low BB Credit Threshold

field of the Configure Open

Trunking dialog box.

Invalid value for day

(1-31).

At the Configure Date

and Time dialog box,

the DD value (day)

must be an integer

from 1 through 31

inclusive.

Verify and enter a valid date.

Table 10: Element Manager Messages (Continued)

Message

Description

Action

This manual is related to the following products: