beautypg.com

HP StorageWorks 2.140 Director Switch User Manual

Page 110

background image

Monitoring and managing the Director

108

Director Element Manager User Guide

FPM—G_Port, small form factor pluggable (SFP) optics, fibre port
module, 1 Gigabit

UPM—G_Port, small form factor pluggable (SFP) optics, universal
port module, 2 Gigabit

GSFM—G_Port, short wave, small form factor, multimode, 1 Gigabit

GLSR—G_Port, short wave, single mode, MT-RJ connector,
1 Gigabit

GXXR—G_Port, mixed mode, MT-RJ connector, 1 Gigabit

GXXL—G_Port, mixed mode, LC connector, 1 Gigabit

Cooling FAN—Fan module.

PWR—Power supply module.

Position—A number representing the FRU chassis position. The chassis (slot)
position for a nonredundant FRU is 0. The chassis positions for redundant
FRUs are 0 and 1. For the Director 2/64 chassis, port positions are 0–63. For
the Director 2/140 model, port positions are 0–127 and 132–143. Note that for
the Director 2/140, ports 128–131 are internal ports and are not available for
external connections.

Status—The FRU status (Active or Backup).

Part Number—The FRU part number.

Serial Number—The FRU serial number.

To display the FRU Properties dialog box for an FRU:

Click the FRU’s row and choose Product > FRU > FRU Properties.

Or

Double-click an FRU.

This manual is related to the following products: