Configuring the Director

143

Director Element Manager User Guide

Move your mouse pointer over the squares in the array to display the
corresponding address. Right-click the array to display the following menu
options:

Prohibit row—Prohibits connection between all addresses in a row. In

effect, this prohibits connection between a specific address and all other
port addresses.

Allow row—Allows connection for all port addresses on a row that are

currently prohibited. This allows connection between a port with a
specific address and other allowed ports.

Prohibit all—Prohibits connection between all port addresses. In this

state, ports in the switch cannot connect with any other port address.

Allow all—This allows a dynamic connection through all port addresses

from which connection is currently prohibited. The allowed attribute has
the lowest precedence and does not override any other attribute.

Block all ports—Blocks communication between all ports. Ports that are

blocked continuously transmit offline sequences (OLS).

Unblock all ports—Unblocks all port addresses that are currently

blocked. This allows communication from all port addresses in the switch.

Clear all—Clears the prohibit and blocked status of all port addresses in

the switch.

CUP Name—This user-defined name is assigned to the control unit port
(CUP). Up to 24 alphanumeric characters allowed, including spaces, hyphens,
and underscores. A space is not allowed as the first character, and the
characters are case-sensitive. This is not a required field.

Activate—Click to activate the current configuration. A warning displays
before the action occurs.

Save As—Click to save the current configuration with a name and
description. The saved configuration will be stored on the HAFM appliance
and in the Address Configuration Library. See “

Managing Stored Address

Configurations (FICON Management Style)

” on page 145” for information

on accessing this library.

Cancel—Click to cancel the configuration settings and close the dialog box
without saving. If you click this button after you click Save As, your changes
will be saved and the dialog box will simply close.