Setting parameters, Confirming the settings, Figure 7-4 – HP StorageWorks XP48 Disk Array User Manual
Page 115
Managing File Systems 115
Figure 7-4
Add File System - Step 3 of 3 (Summary of Changes)
The procedure for confirming the settings is described below. The device file might have to be recognized in
the middle of operations. The operation related to recognizing the device file differs depending on the system
components. For details on the required operation, see section 11-2 , Function-Specific Summary of
Troubleshooting Steps , and then see the manuals for the hardware and software that are being used (HBA,
volume manager, operating system documentation, etc.).
The following explains how to confirm the settings when the device file needs to be identified and when the
device file does not need to be identified.
To confirm the settings when the device file does not need to be recognized on the host side:
1.
Check the contents of the Add File System - Step 3 of 3 dialog box (see
2.
If there is no problem, select the I have checked the above warning, and still want to proceed checkbox
located below the warning message.
WARNING!
Make sure that the physical volume corresponding to the specified LDEV is not being used
by another program. If you specify and operate an LDEV that is already being used, the data cannot be
guaranteed and operations might not be performed properly.
Also, if you click the Confirm button without selecting the check box, an error occurs.
3.
Click the Confirm button.
A message is displayed indicating that the add file system process is underway.
IMPORTANT:
To check the execution status of the processing, check the transaction logs. For details
on transaction logs, see section
When the processing has been completed, the Add File System - Result dialog box is displayed,
displaying the processing results.
4.
In the Add File System - Result dialog box, check the displayed information.
5.
Click the Close button.
The window closes. The add file system process has been completed.
To confirm the settings when the device file needs to be recognized on the host side:
1.
Check the contents of the Add File System - Step 3 of 3 dialog box (see
2.
If there is no problem, select the I have checked the above warning, and still want to proceed checkbox
located below the warning message.
WARNING!
Make sure that the physical volume corresponding to the specified LDEV is not being used
by another program. If you specify and operate an LDEV that is already being used, the data cannot be
guaranteed and operations might not be performed properly.