Counter
90
Summit T28 PCI Express Multi‐Lane Protocol Analyzer User Manual
Figure 5.44: Incrementing and Resetting Global and Sequence State Counters
Note:
Listed below are some of the considerations to note about the counter functionality
1. If a counter is reset, it will restore to it's original value, in this case the value defined
by the user.
2. Resetting a counter will stop it and set it to it's original value.
3. Local counters for a particular state will automatically reset if the sequencer
advances to another state. Example: "Counter A" in State 1 and "Ccounter A" in State
2 are different timers not related to each other.
4. Local counters are controlled by events defined in the same state where the
counters are defined.
In case of competing actions to control global counters using the same event from global
and local states, the control from local states takes priority.
5.22.3 Changing the Value of the Counter
To change the value of the counter:
1. Double‐click on the Counter.
2. Enter a new value in the pop‐up dialog. This causes the new value to appear in the
counter button.