Profibus signal i/o map – FEC FUSIONE-HS-2 User Manual
Page 81

FEC FUSION Operations Manual
Chapter 4: System Setup and Wiring (Rev. 2.1)
Page 4-43
Profibus Signal I/O Map
(Continued)
Word
Byte
Bit No.
Signal Description
Comment
4
8
0
65
Angle Integer bit 0
Outputs Fastening Angle value using
binary integer
0 - 9999 max.
Example:
bit 1, 2, 5, 7 Logical "1" = 166
1
66
Angle Integer bit 1
2
67
Angle Integer bit 2
3
68
Angle Integer bit 3
4
69
Angle Integer bit 4
5
70
Angle Integer bit 5
6
71
Angle Integer bit 6
7
72
Angle Integer bit 7
9
0
73
Angle Integer bit 8
1
74
Angle Integer bit 9
2
75
Angle Integer bit 10
3
76
Angle Integer bit 11
4
77
Angle Integer bit 12
5
78
Angle Integer bit 13
6
79
7
80
5-7
Byte
10-15
81
Not Used
128
From PLC to Fusion: 2 Words (4 Bytes – 32bits)
Word Byte Bit No. Description
Comment
0
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
Abort Job
Reserved for Future Use
7
8
Reset
1
0
9
1
10
2
11
3
12
4
13
Work Select/Job 0
Job Function is Future
5
14
Work Select/Job 1
Job Function is Future
6
15
Work Select/Job 2
Job Function is Future
7
16
Work Select/Job 3
Job Function is Future
1
2
0
17
Stop
1
18
Reset
2
19
Reverse
3
20
Start
4
21
Bypass
5
22
Disable Self-check
6
23
7
24
3
0
25
1
26
2
27
3
28
4
29
In 12
Terminal Input 12 not assigned
5
30
In 13
Terminal Input 13 not assigned
6
31
In 14
Terminal Input 14 not assigned
7
32
In 15
Terminal Input 15 not assigned
`