FEC FUSIONE-HS-2 User Manual
Page 142
Chapter 7: System Operations
Page 7-18
Data No.18 CROS Torque
[Nm, Kgm...]
Setting range: 0 ~ [10: Calibration torque] × 1.0
2nd stop / synchronization point for multiple step fastening operations.
End point for 2nd torque rate calculation. [1E: 2
nd
Rate Start Torque is beginning]
Start point for 3
rd
Torque Rate calculation. [Fastening End is the stop point]
Data No.24 CROS Angle
[deg]
(NOT USED as standard function)
Setting range: 0 ~ 9999
2nd stop / synchronization point for multiple step fastening operations.
End point for 2nd torque rate calculation. [1E: 2
nd
Rate Start Torque or 26: 2
nd
Rate Start Angle
is the beginning]
Start point for 3
rd
Torque Rate calculation. [Fastening End is the stop point]
Data No.19 Torque Inhibit Limit
[Nm, Kgm...]
Setting range: 0 ~ [10: Calibration torque] × 1.1
Limit for ignoring the Torque value sensed during fastening start due to inertia. When the initial
Torque exceeds the Torque Inhibit Limit during [61: Torque Inhibit Revolutions] an ABNORMAL
will be generated and fastening will end.
Data No.1A Not Used
Data No.56 Not Used
Angle
Torque
34 Rate 3 Low Limit
35 Rate 3 High Limit
24 CROS
22 Standard
Torque
Angle
13 Standard
18 CROS
34 Rate 3 Low Limit
35 Rate 3 High Limit
If 3rd
t
Torque Rate monitoring is not required, [18:CROS Torque] should be set the
same or higher than [10: Calibration Torque]