4.8.4 Rear Panel RS232 Abbreviated Communication Protocol
The RS232C output format can be switched between the standard format (preceding page)
and the abbreviated format shown below. This function is available in firmware versions 2.22
or later. The table below describes the data set-up for enabling and configuring the abbre-
viated output format.
Work #
Data #
Item
Setting
00
40
Format selection
0: Standard (214 bytes) Data # 41 ~ 49 Disabled
1:Abbreviated (32bytes) Data # 41 ~ 49 Enabled
00
41
End data selection
0: 0Dh (CR) 1: 0Ah (LF) 3: 0Dh+0Ah (CR & LF)
00
42
Comm. Speed
1: 9600 BPS 2: 19200BPS 3: 38400BPS
00
43
Data bit
0: 7Bit 1: 8 Bit
00
44
Stop bit
0: 1 Bit 1: 2 Bit
00
45
Parity
0: None 1: Even 2: Odd
00
46
Torque data
0: No data 1:Enable data
00
47
Angle data
0: No data 1:Enable data
00
48
Cycle Time data
0: No data 1:Enable data
00
49
Judgment
0: No data 1:Enable data
Example of abbreviated format:
Byte
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Desc.
Spindle # Work
Cycle Count
Peak Torque
Final Angle
ASCII
Hex
23H 31H 31H 30H 31H 32H 31H 32H 2EH 33H 34H 31H 31H 32H 2EH 33H
Data
#
1
1
0
1
2
1
2
.
3
4
1
1
2
.
3
Byte
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Desc.
Not Used
Cycle Time
Judge
ASCII
Hex
30H 30H 30H 30H 30H 30H 30H 30H 30H 31H 32H 2EH 33H 40H
Data
0
0
0
0
0
0
0
0
0
1
2
.
3
@
Byte
31
31
31
32
Desc.
ASCII
Hex
0DH OR 0AH OR 0DH 0AH
Data
CR
LF
CR
LF
Definition of “Judge” (Byte 30):
@ = Accept G = Stop
E = Low Time Reject F = Time Reject
P = Bypass
K = Angle High Reject J = Angle Low Reject
I = Torque High Reject H = Torque Low Reject
A = Abnormal X = Other Reject