4.11.2 Considerations for Cable Trolleys
•
Cables hung by festooning type systems must be secured to the individual cable trolley
and positioned to avoid sharp bends and eliminate or minimize any torsion twisting.
•
Restraint cords should be used in between cable trolleys to limit movement and reduce
the stress on cables as they are extended. Restraint cord lengths must always be shorter
than the length of cable hung between trolleys.
•
Cable loops should be consistent in length,typically not exceeding 5 feet in depth between
trolleys. Sufficient number of trolleys should be used in a system to support the entire
length of moving cable and to allow relaxed stacking/festooning of cable loops when tool is
in the retracted position.
•
One trolley should be fixed to the runway rail to eliminate tugging on or stretching of
cables.
4.11.3 Considerations for Flexible Cable Tracks
•
Cables must
under no circumstances
have the opportunity to tangle. Therefore the
clearance height of a track compartment with several similar cables next to one another
must not amount to more that one and a half times the cable diameter
.
•
There should be an “all around” minimum clearance between cables of 10% of the cable’s
diameter.
•
Cables and hoses with very different diameters should be laid separately. Separation is
achieved by using Flexible Track separators. The following rules should be followed for
cable separation:
o
If (Cable 1 Diameter) + (Cable 2 Diameter) > 1.2 x Track Inner Height, then
no separation is necessary.
o
If (Cable 1 Diameter) + (Cable 2 Diameter) 1.2 x Track Inner Height, then a
horizontal or vertical separator must be used to reduce the inner height, the-
reby preventing the entanglement of the cables.
•
The cable weight should be symmetrically distributed along the width of the track.
•
Cables must be able to move freely along the radius.
•
The cables must be secured with strain relief at both ends. In exceptional cases, the
cables may be fixed with strain relief at the moving end only. Unless using a Flexible Ca-
ble Track with integrated strain relief, a gap of 10~30 x cable diameter between the end of
the bending segment and the fixed point is recommended for most cables.
•
Under no circumstances should excess cable be put into a Flexible Cable Track.
4.11.4 Considerations for Cable Trays & Ladders
•
Cable drop out panels should be used where cables enter and exit a tray or ladder sys-
tem. Sharp bends need to be avoided whenever possible.
•
Cables should be secured at both entry and exit points of a tray or ladder.
•
Avoid running high voltage or high frequency cables in the same tray or ladder as signal or
control cables unless cables are designed for such environments.
•
If excess cable is to be stored in a tray or ladder, do not tightly coil cable. Cable should be
laid in as large of a loop as possible.