Data No.1B Breakaway Torque Limit
[Nm, Kgm...]
Setting range: 0 ~ [10: Calibration torque] × 1.1
When this torque is exceeded during Reverse 2 or 3 operations, an Abnormal will be
generated that will stop the operation.
Data No.1C Final Low Torque
[Nm, Kgm...]
Data No.1D Final High Torque
[Nm, Kgm...]
Setting range: 0 ~ [10: Calibration torque] × 1.1
For [Angle Method], sets the High and Low limits for Torque at the point that the final Fastening Angle
is achieved.
For [Torque Method], during Torque Recovery, sets the High and Low limits for Torque at the
point that the final Fastening is completed.
Data No.1E 2ND Rate Start Torque
[Nm, Kgm...]
Setting range: 0 ~ [10: Cal torque] × 1.0
Start point for 2
nd
Torque rate monitoring [Crossover is the end]
Data No.26 2ND Rate Start Angle
[deg]
(NOT USED as standard function)
Setting range: 0 ~ 9999 degrees
Start point for 2
nd
Torque rate monitoring [CROS Torque/Angle is the end]
Torque
Angle
26 2ND
24 CROS
32 Rate 2 Low Limit
33 Rate 2 High Limit
Angle
18 CROS
1E 2ND
32 Rate 2 Low Limit
33 Rate 2 High Limit
Torque
If 2nd Torque Rate monitoring is not required, [1E:2
nd
Rate Start Torque] should be
set the same or higher than [10: Calibration Torque]