FEC FUSIONE-HS-2 User Manual
Page 181
FUSION Operations Manual Chapter 9: Troubleshooting (Rev. 2)
Page 9-13
9.10 Parameter Error
9.10.1 Code 9-0
PARAMETER ERROR / MISSING SPEED PRESET
.
Some speed preset is not setup in the parameter number selected or the wrong parameter
number has been selected by the PLC.
RECOVERY:
1. Verify that the parameter number that is being selected by the PLC is configured in the
controller.
2. Check that the reverse speed preset is not <0> or out of the specified speed range of the
tool
.
9.10.2 Code 9-1
PARAMETER ERROR / MISSING TIME or SPEED PRESET
Some Time or Speed preset is not setup in the parameter number selected or the wrong pa-
rameter number has been selected by the PLC.
RECOVERY:
1. Verify that the parameter number that is being selected by the PLC is configured in the
controller.
2. Check that the reverse speed preset is not <0> or out of the specified speed range of the
tool
.
9.10.3 Code 9-2
PARAMETER ERROR / PARAMETER SELECT ERROR
The parameter selected was empty.
RECOVERY:
1. Verify that the parameter number that is being selected by the PLC is configured in the
controller.
2. Check that the fastening presets are not <0> or out of the specified range for the tool.
9.10.4 Code 9-3
PARAMETER ERROR / MISSING REVERSE SPEED
The Reverse speed preset is missing.
RECOVERY:
1. Verify that the parameter number that is being selected by the PLC is configured in the
controller.
2. Check that the reverse presets are not <0> or out of the specified range for the tool.
9.10.5 Code 9-4
PARAMETER ERROR / TORQUE SPEED NOT SET
The Torque speed preset is missing.
RECOVERY:
1. Verify that the parameter number that is being selected by the PLC is configured in the
controller.
2. Check that the Torque speed is not set as <0> or out of the specified range for the tool.