I/o signal map, Firmware set-up – FEC FUSIONE-HS-2 User Manual
Page 85

FEC FUSION Operations Manual
Chapter 4: System Setup and Wiring (Rev. 2.1)
Page 4-47
I/O Signal Map
(Continued)
From PLC to Fusion – (4 Bytes – 32 Bits)
Octal Bit Description
Comment
O:00
0
0
1
1
2
2
3
3
4
4
5
5
6
6
Abort Job
Reserved for Future Use
7
7
Reset
O:00
10
8
11
9
12
10
13
11
14
12
Work Select/Job 0
Job Function is Future
15
13
Work Select/Job 1
Job Function is Future
16
14
Work Select/Job 2
Job Function is Future
17
15
Work Select/Job 3
Job Function is Future
O:01
0
0
Stop
1
1
Reset
2
2
Reverse
3
3
Start
4
4
Bypass
5
5
Disable Self-check
6
6
7
7
O:01
10
8
11
9
12
10
13
11
14
12
In 12
Terminal Input 12 not assigned
15
13
In 13
Terminal Input 13 not assigned
16
14
In 14
Terminal Input 14 not assigned
17
15
In 15
Terminal Input 15 not assigned
Firmware Set-up
Two items are configurable in the set-up of the Fusion controller for the Allen Bradley Remote
I/O interface. Both the I/O Rack Starting Quarter and the Last Rack setting is set-up in the
system parameter settings.
I/O Starting Quarter
Sets the Starting Quarter for the rack address
WORK [00] Data No. [28]
“0”: 1
st
Quarter
“1”: 2
nd
Quarter
“2”: 3
rd
Quarter
“3”: 4
th
Quarter
Last Rack
Sets the Fusion system as the last rack or not on the Remote I/O link
WORK [00] Data No. [29
]
“0”: Not Last Rack
“1”: Last Rack