FEC FUSIONE-HS-2 User Manual
Page 34

Chapter 3: System Description
Page 3-4
FRONT PANEL DISPLAY FEATURES
ITEM ITEM AS MARKED ON UNIT
DESCRIPTION
1
ACCEPT
(Green) Lights to indicate that the spindle has completed an
acceptable fastening cycle. Flashes for an individual accept
during a Batch Count.
2
WORK ACCEPT
(Green) Lights to indicate that the spindle has completed an
acceptable group of fastenings. (Reached Batch Count No.)
3
REJECT
(Red). Indicates the spindle performed a rejected fastening, out
of the operation limits. Flashes indicating a rate reject.
4
TORQUE
(Yellow). Indicates the “Data Display LED” is displaying Torque
fastening Data.
5
ANGLE
(Yellow). Indicates the “Data Display LED” is displaying Angle
fastening Data.
6
LED Display
Four digit display which function is dependent upon the D-NO
selected.
“
” is displayed here during an “Abnormal” condition.
7
WORK
Displays two-digit parameter number and, as required, will
override parameter output to display an Abnormal code.
8
COUNT/D-NO.
Display number that indicates which data in the "DATA" display
field is being displayed and as required, will display an Abnormal
Sub-code. Displays Fastening Count during Batch Count
function.
FRONT PANEL CONTROL FEATURES
9
CAL
Manual calibration (CAL) check pushbutton
10 RESET
Manual zero check and system reset pushbutton.
11 UP - Arrow
Data change increase pushbutton.
12 DOWN - Arrow
Data change decrease pushbutton.
13 MODE
Display mode selection pushbutton.
14 SET
Data change confirmation set pushbutton.
15 WORK RIGHT - Arrow
Parameter selection increase pushbutton.
16 WORK LEFT - Arrow
Parameter selection decrease pushbutton.
17 POWER 0 / 1
0-Off / 1-On controller power switch
FRONT PANEL CONNECTOR FEATURES
18 T/A MON.
Optional DB9 connector for Torque / Angle monitor.
Analog outputs for use with external analysis equipment.
19 PC
RS232 communications port for interfacing with the AFC user
console software.