FEC FUSIONE-HS-2 User Manual
Page 63

FEC FUSION Operations Manual
Chapter 4: System Setup and Wiring (Rev. 2.1)
Page 4-25
4.8.5 Rear Panel RS232 Alternate Communication Protocol
An alternate communication protocol is available upon set-up in a different “Fastening Func-
tion Mode” (See 7.2.5 Fastening Function Version [Work]-00, [D-No]-03) If the system is set-
up in a “DDK” mode, this protocol becomes the Standard Communication Protocol.
This alternate protocol has 79 bytes of data per fastening.
Byte
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Desc.
Cycle Count
Spindle
Number
Work
Number
ASCII
Hex
30H 30H 30H 31H 20H 20H 30H 31H 20H 20H 20H 31H 20H 20H
Data
0
0
0
1
0
1
1
Byte
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Desc.
Peak Torque
Judge
Final Angle
Judge
ASCII
Hex
31H 32H 2EH 33H 34H 4CH 20H 20H 20H 20H 35H 30H 48H 20H
Data
1
2
.
3
4
L
5
0
H
Byte
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Desc.
Final Torque
Judge
1st Rate
Judge
ASCII
Hex
31H 32H 2EH 33H 34H 20H 20H 20H 30H 2EH 31H 32H 33H 20H 20H 20H
Data
1
2
.
3
4
0
.
1
2
3
Byte
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Desc.
2nd Rate
Judge
3rd Rate
Judge
ASCII
Hex
30H 2EH 31H 32H 33H 20H 20H 20H 30H 2EH 31H 32H 33H 20H 20H 20H
Data
0
.
1
2
3
0
.
1
2
3
Byte
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75 76
77
78 79
Desc.
1st Time
Judge
2nd Time
Judge
Final
Judge
CR LF
ASCII
Hex
20H 31H 30H 2EH 30H 20H 20H 20H 20H 20H 32H 2EH 30H 20H 20H 20H 58H 0DH 0AH
Data
1
0
.
0
2
.
0
X
Final Judgment: “X” Reject = 58H, “O” Accept = 4FH, “A” Abnormal = 41H, “S” Stop=53H, “B” Bypass=42H