FEC FUSIONE-HS-2 User Manual
Page 146

Chapter 7: System Operations
Page 7-22
Data No.55 Not Used
Data No.56 Not Used
Data No.60 Freerun Revolutions
[rev]
Setting range: 0 ~ 99.9
Sets the number of revolutions the system will run from the beginning of the fastening operation until
[51:Freerun Speed] is no longer needed.
Override shifts to [52: Slow Down Speed] when [14:Speed Change Torque] is sensed.
Data No.61 Torque Inhibit Revolutions
[rev]
Setting range: 0 ~ 99.9
For operation that require large starting torque.
Duration for ignoring the Torque value sensed at Fastening start due to inertia. When the initial Tor-
que exceeds the [19: Torque Inhibit Limit] during [61: Torque Inhibit Revolutions] an ABNORMAL will
be generated and fastening will end.
Data No.62 Not Used
Data No.63 Not Used
Data No.64 Not Used
Data No.68 Not Used
Data No.69 Not Used
Data No.70 Full Scale Current
[A]
Data No.71 High Current Limit
[A]
Data No.72 Low Current Limit
[A]
Data No.73 Fastening Current Limit
[A]
Setting range: 0 ~ 12
Used as a redundant check of the fastening process. Please contact FEC Inc. for assistance.
Unit Type
Tool Type
Full Scale
Current [A]
High Current
Limit [A]
Low Current
Limit [A]
Fastening
Current [A]
HFC-EC-16
HFT
12.0 max
12.0 max
0.0
12.0 max
Data No.74 Accept Batch Count
Setting Range: 0 – 99
Used to set the number of accepts for WORK ACCEPT. Setting “0” disables function.
Data No.80 CW Stop Angle (Pistol Pulse Function)
[Deg]
Setting Range: 0 – 360
Used to set the swing stop angle in the CW direction. This is the angle the pistol will swing up to be-
fore shutting off. Setting “180” disables function.
Data No.81 CW Swing Pause Angle (Pistol Pulse Function)
[Deg]
Setting Range: 0 – 360
Used to set the swing Pause angle in the CW direction.
Data No.82 CW Swing Stop Servo Lock Time (Pistol Pulse Function)
[Deg]
Setting Range: 0 – 1000
Used to set the swing stop servo lock time in the CW direction.