3 fastening results display mode – FEC FUSIONE-HS-2 User Manual
Page 131

FUSION Operations Manual Chapter 7: System Operations (Rev.2)
Page 7-7
7.2.3 Fastening Results Display Mode.
In
Fastening results display mode
(when [COUNT/D-NO] shows
_0
~
≡≡≡≡6666
), data can be ob-
tained by pressing the [
↓↓↓↓
] and [
↑↑↑↑
] keys to scroll the [COUNT/D-NO] until the desired DATA
item is displayed. The following information will be displayed in the [DATA] display section
for the displayed [D-NO]:
D-No
DATA
_0
PEAK TORQUE.
_1
FINAL ANGLE
_2
1ST TORQUE RATE
_3
2ND TORQUE RATE.
_4
1ST STEP TIME.
_5
FINAL STEP TIME.
_6
CYCLE TIME
_7
FASTENING MODE.
_8
3RD TORQUE RATE
_9
NOT USED
====0
FASTENING MODE.
=1
FASTENING STEPS
=2
NOT USED
=3
SELF CHECK (ON: enabled, OFF: disabled)
=4
REVERSE FLAG (ON:Reversed, OFF: Not Reversed
=5
CAUSE OF FASTENING STOP:
0: RESET / NO DATA / AFTER REVERSE.
1: ABNORMAL SIGNAL.
2: BYPASS SIGNAL.
3: STOP SIGNAL.
4: REJECT.
5: ACCEPT.
=6
TORQUE JUDGE tq H/L (FINAL) H/L (PEAK)
=7
ANGLE JUDGE AN H/L
=8
RATE JUDGE r H/L (1ST) H/L (2ND) H/L (3RD)
=9
TIME JUDGE ti H/L (1ST) H/L (FINAL)
≡≡≡≡0
1ST INCREMENT TORQUE.
≡≡≡≡1
2ND INCREMENT TORQUE.
≡≡≡≡2
1ST FINAL TORQUE
≡≡≡≡3
1ST PEAK TORQUE.
≡≡≡≡4
FINAL TORQUE.
≡≡≡≡5
ANGLE AT PEAK TORQUE
≡≡≡≡6
PEAK CURRENT
FIG. 7-2-3 Fastening results display selection