Chapter 4: System Setup and Wiring
Page 4-14
4.7.3 Bank Select Table
Bank Select inputs are used to “multiplex” the output signals allowing up to 32 signals from
only 8 physical outputs. By changing the input conditions of the two Bank Select inputs, up to
four “Banks” may be selected, changing the definition of each output point.
BANK
SEL.
INPUT
PLC / CONTROLLER UNIT BANK DATA
BANK
NO.
SEL 1
B4
SEL 0
A4
Output
A11~B14
NAME OF
SIGNAL
DESCRIPTION
1
OFF
OFF
REJECT
Output when the fastening result is a REJECT.
Indicates that the spindle has failed the
fastening limits. This output remains active
until the START signal or RESET signal is
input.
ACCEPT
Output when the fastening result is a ACCEPT.
Indicates that the spindle is within the fastening
limits. This output remains active until the
START signal or RESET signal is input.
ABNORMAL
Output when an Abnormal condition occurs,
indicates that the System has detected an
internal fault, and can no longer proceed. An
Abnormal condition must be corrected before
the System will resume normal operation.
READY
Output when the system is in READY condition
to operate, and inputs are enabled. This signal
is inactive (off) when the BUSY output is active
(on).
BUSY
Output after a START signal is received, and
active until the fastening cycle is complete and
the READY signal is output.
TORQUE
HIGH
REJECT
Output when Fastening resulted in a Torque
High Reject.
TORQUE
LOW
REJECT
Output when Fastening resulted in a Torque
Low Reject.
BYPASS
Output when the spindle is bypass either via
PLC input or the Controller Unit front panel
switch.
2
OFF
ON
NOT USED
1ST TIME
OVER
REJECT
Output when Fastening resulted in a 1st Time
Reject.
FINAL TIME
OVER
REJECT
Output when Fastening resulted in a Final Time
Reject.
WORK 0
Output confirmation of WORK SELECT 0~3
(Pins 9 and 14~16) input selections.
WORK 1
WORK 2