3. Menu W
indow
72
[10] Initialize Memory (I)
ƒ Position (O)
Clear all position data.
This item is displayed on the XSEL-R/S, RX/SX and RXD/SXD
controllers.
(Note) If 6BD, "Position data configuration change error" or
6BF, "Position data sum check error" occurs, use this
command to initialize the position data.
(Note) 22B, "Position data comment loss error" will occur if
the software is reset or power is turned off after this
operation, without writing the position data to the flash
ROM first.
ƒ Coordinate System Definition Data (C)
Clear all coordinate system definition data.
This item is displayed on the XSEL-RX/SX and RXD/SXD
controller.
(Note) if D40, "Coordinate system data management area
sum check error," D41, "Coordinate system data
management area ID error" or D42, "Coordinate data
sum check error" occurs, use this command to
initialize the coordinate system definition data.
ƒ Global Variable and Flag (V)
Clear all global variables and flags to zero.
ƒ User Data Retained Memory (U)
In the case of X-SEL-P/Q/PX/QX and R/S/RX/SX/RXD/SXD
with gateway function, clear all the contents of user data
retained memory containing RC-axis position data in X-SEL
controller.
(PC interface software version 7.2.0.0 or later)
* If the Edit screen for RC-axis position (in
X-SEL-P/Q/PX/QX and R/S/RX/SX/RXD/SXD controllers)
is opened without resetting the software or turning off the
power after performing this operation and writing to the
flash ROM, "RC Position NO. Error" message will be
displayed.
* If the software is reset or the power is turned off without
writing to the flash ROM after performing this operation, the
last written data in the flash ROM will be retained.
If the user data retained memory is initialized by a mistake,
reset the software without writing to the flash ROM.
ƒ Parameter (at the time of shipment) (S)
Can return parameters to the ones at the time of shipment.
This item is not displayed normally. It is a function which will
become available by inputting a password. (Refer to "8.4 How
to Initialize X-SEL-R/S, RX/SX, RXD/SXD and
SSEL/ASEL/PSEL Parameters (at the time of shipment).")
It is a function of X-SEL-R/S, RX/SX, RXD/SX, SSEL, ASEL,
and PSEL controllers.