IAI America IA-101-X-USBMW User Manual
Page 77

3. Menu W
indow
69
The following section explains about "Transfer to Controller" and "Divide File."
ƒ Transfer to Controller
On the Data Transfer/Division Selection Screen, click Transfer to
Controller. The File Setup Screen will appear.
Select Backup All Saved Data (all data including programs, positions,
etc.) and transfer to the controller. (If you are not selecting all data, click
to select the data to be transferred. The selected data will be marked
with 3.)
(Note) The parameter can not be sent if the selected parameter in
the controller is the same as the axis pattern.
(Note) Data saved in the regular format can be transferred to the
X-SEL-P/Q, PX/QX controller with the gateway function
compatible with increased memory.
Program of No. 65 or later will display a screen to ask if the
position of No. 4001 or later should be erased. Clicking Yes
will clear all the programs of No. 65 or later and positions of
No. 4001 or later. Clicking No will not clear them.
Fig. 3.22 Confirmation Screen
(Note) Data saved in the extended format can be transferred to the
controller incompatible with increased memory.
Programs of No. 65 or later and positions of No. 4001 or later
cannot be transferred.
Parameters not supported by the controller at the destination
cannot be transferred.
The following warning screen will be displayed. Click Yes to
transfer data.
Fig. 3.23 Confirmation Screen
[In the case of X-SEL-P/Q/PX/QX and R/S/RX/SX/RXD/SXD controllers with the gateway function]
The following confirmation screen will be displayed after the program, parameter, position and symbol are
transferred, written to FROM and restarted.
[When RC-axis position data in X-SEL is used]
Click OK to transfer the RC-axis position data in X-SEL.