Appendix – IAI America IA-101-X-USBMW User Manual
Page 233
16.
Appendix
225
16. Appendix
16.1 Parameter Recovery Method for X-SEL-P/Q, PX/QX, R/S, RX/SX and RXD/SXD
Controllers
If parameter data is lost during parameter writing to the flash ROM due to main power OFF or any other factor,
all parameters will be rewritten to initial values. In the case of the X-SEL-P/Q or PX/QX controller, an error will
be detected after power reconnection or software reset since system-specific settings are lost immediately
after parameter initialization.
Under such conditions, all parameters cannot be transferred to the controller.
The recovery method in that case is explained below.
Note: This method is intended to write the parameter data back to the controller for recovery. Please note
that serious effects such as home displacement, inoperability and error occurrence may result when
recovery parameters are transferred to any controller other than the target one, even if the model is
the same