With J/K type X-SEL controllers, executing the command "OPEN 1" (channel 1 is shared with the PC
software) in a SEL program in the MANU (manual) mode will forcibly switch the right of control over serial port
channel 1 to the SEL program and disconnect the communication link between the controller and PC
software. The program will continue to run. ("Error No. A5D "SCIF open error in non-AUTO mode" will occur.)
To stop actuator operation, always use the emergency-stop button. (In particular, exercise due caution when
stopping a jogging actuator.)
* This error code is applicable in main controller application 0.16 or earlier.
In the case of a P/Q controller, a J/K controller running main controller application version 0.16 or later or a
table top model robot, opening the TP port (teaching connector) may result in the following conditions
depending on whether or not the servo is in use.
Before the OPEN command
After the OPEN command
TP port connection
Connected to the PC
software
Forcibly switched to SEL program
connection (message error).
The program continues to run.
Error No. A50 "SCIF open error in non-AUTO mode" will occur following the OPEN command.
Before the OPEN command
After the OPEN command
TP port connection
Connected to the PC
software
Connection to the PC software
(cold start error). The program end.
Error No. E89 "SCIF open error in non-AUTO mode" will occur following the OPEN command. (Servo in
use)
The channel number assigned to the TP port will vary depending on the controller type.
J/K type, Table top actuator (TT):
Channel 1 ("OPEN 1")
P/Q type, PX/QX type, R/S type, RX/SX type, RXD/SXD type, SSEL, ASEL, PSEL: Channel 0 ("OPEN 0")
The "Important" information provided in the above box applies to a condition where the controller is in the
MANU mode and I/O parameter No. 90 is not set to "2" (IAI protocol).
Important