IAI America IA-101-X-USBMW User Manual
Page 173

11. Monitor
165
Save the maintenance
information data to a file
(CSV format).
Transfer the data of entered new
values to the controller.
Print the maintenance
information data.
Initialize all maintenance information
data. (This button is displayed only
when there is a maintenance
information data error.)
A new value can be entered by the following methods:
• Double-click the cell.
• Press the "Ctrl" and "Space" keys together.
• Press a number key.
Only the alert function threshold can be changed.
If the system memory backup battery is installed, the error list contents will not be cleared even if the
power is turned OFF.
When clearing the error list contents, click the alarm list clear
key. A warning in Fig. 11.18 will be
displayed. Clicking Yes will clear the error list contents.
Fig. 11.21 Confirmation
* When trouble occurs, you may be requested to send the error list saved in a file to resolve the problem at
an early stage. The error list file cannot be opened by this PC interface software.
(8) Maintenance information screen
The total number of times the actuator has moved, and total distance travelled by the actuator, are
displayed.
This screen is displayed on the X-SEL-R/S, RX/SX or RXD/SXD controller.
Fig. 11.22 Maintenance Information
Total number of movements: Indicates the accumulated total of times the actuator has moved
Thresholds for total number of movements: Indicates the thresholds for the total number of movements
Total distance traveled [m]: Indicates the accumulated total of distance travelled by the actuator
Thresholds for total distance traveled [m]: Indicates the thresholds for the total distance travelled