Hitachi GR2000 Series User Manual
Page 179

Troubleshooting
GR2K-GA-0015
7-13
Ver. 07-02
(b) Line Status Checkout:
Check out the Line status using a show interfaces command. The remedy for Line
status is shown in the table below.
Table 7-9 WAN NIF Status Checkout/Action
No.
NIF Status
Cause
Action
1
active
This NIF is operating normally.
Inspect line status according to Table 7-9.
2
mismatch
For installed NIF, configured line cannot
be used under control of this NIF.
(Installed NIF and line configuration
information do not match.)
Check whether installed NIF is correct, or line
configuration information is correct.
3
unused
Line configuration information is not
defined to this NIF.
Define configuration information for the line to be
used.
4
closed
Operation of this NIF is suspended by
the close nif command.
Ensure that NIF board to be used is installed, and set
this NIF to active by using free nif command.
5
fault
This NIF is faulty.
Obtain the log message for the subject line using
show logging command (*1), and take necessary
troubleshooting actions in accordance with the
obtained log message (Chapter 5, “Log Messages,” in
GR2000 Operations Log and MIB Reference).
6
initialized
This NIF is restarting after error
detection.
Same as above.
7
locked
Operation of this NIF is suspended by
configuration information.
Ensure that NIF board to be used is installed, and set
this NIF to active by altering the configuration
information.
*1:
For details of show logging command, see GR2000 Operations Commands, Vol. 1.
Table 7-10 WAN Line Status Checkout/Action
No.
Line Status
Cause
Action
1
active up
This line is operating normally.
When the line has a timeslot (*1), inspect the status of
the timeslot according to Table 7-11
When the line has a subline (*2), inspect the status of
the subline according to Table 7-12.
When the line does not have a timeslot, inspect link
layer protocol status of that line according to Table
7-13 to Table 7-15.
2
active down
This line has line error.
Obtain the log message for the subject line using
show logging command, and take necessary
troubleshooting actions in accordance with the
obtained log message (Chapter 5, “Log Messages,” in
GR2000 Operations Log and MIB Reference).
3
mismatch
For installed line, configured line
cannot be used under control of this
NIF.
(Installed line and line configuration
information do not match.)
Check whether installed line is correct, or line
configuration information is correct.
4
unused
Line configuration information is not
defined under this line.
Define configuration information for the line to be
used.
5
closed
Operation of this line is suspended by
close command.
Check that cable is installed to the line to be used,
and set this line to active by using free command.