Gasboy CFN Series Site Controller III Start-up User Manual
Page 92

Start-up Commands
Load Fuel Products, Pumps, Tanks, Prices, and Taxes
Page 86 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008
4
Type RE PU to reset the pumps to zero (
).
If you wish to set the quantity and dollar totalizers maintained by the SC to the same settings 
as the mechanical totalizers on the pump, do a LO PU;C command (
Note: You may load up to five hoses per pump. When you enter the last hose for a particular
pump, press RETURN at the next hose number prompt to get the next Pump Number 
prompt.
Figure 13-14: Example of RE PU Command with Prompt
P* RE PU 
Verify (Y/N)? Y 
P*
Figure 13-15: Example of LO PU;C Command with Prompts
P* LO PU;C 
Pump number? 1 
Hose number? 1 
Quantity? 5624.8 
$amount? 3217.95 
Hose number? 
Pump number? 2 
Hose number? 2 
Quantity? 2345.9 
$amount? 6789.10 
Hose number? 
Pump number? 
P*
5
Type LO TA;C to load the system’s initial quantity, product code and reorder level for each 
tank (tank inventory) (
Figure 13-16: Example of LO TA;C Command with Prompts
P* LO TA;C 
Tank number? 1 
Quantity? 9325 
Product code? 1 
Reorder level? 2000 
Tank number? 
P*
