If a 2-wire device is connected to a loop that is set for 4-wire communication, the
SC will not operate correctly. 4-wire devices on a 2-wire loop may not
communicate with the SC.

CAUTION

Site Information

Authorize Users

Page 12 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008

If your site uses Tokheim

®

Dispenser Payment Terminal (DPT), 2-wire communication is

used. Loop 2 is factory-set for 2-wire communications. Indicate the loop wiring used at the
site. Refer to C09146 Pump Interface Manual for more information.

Loop 1

2/4 wire

Loop 2

2/4 wire

Authorize Users

Note: Refer to MDE-4739 CFN III PCI Secure Controller Software Installation/Upgrade

Instructions Versions 3.5 and above and MDE-4762 Site Controller III Manager’s
Manual for Windows XP Embedded.

Fill in the user’s name, user number (1 - 96), permission level (0 - 10), and set the initial sign-
on code as 1234567 for all users who are authorized to use the data terminal, computer, or
console.

Note: If you communicate with a remote site using site-to-host protocol, you must identify the

remote host (PC, network, and so on) as user 1, with a permission level of 10. This does
not apply to remote hosts used for authorization only (BUYPASS, VISA, and so on).

User Name

User #

Permission

Sign-on Code