Communication Tests

SC III or Remote Terminal

Page 70 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008

SC III or Remote Terminal

1

Verify if the SC III (and remote terminal, if applicable) is connected properly and that the
monitor is displaying a SC III window or full screen.
If it is not, put the arrow on the SC III icon (by moving the mouse) and double-click on the
icon.

2

Press RETURN.
(You may have to set up switches and parameters on the terminal).
The system should respond: sign on.

3

Type GASBOY and press RETURN.
Note: For security reasons, GASBOY will not display as you type it.

The system should respond: Connected to site 1001 on along with the day, date, and time,
followed by the command prompt (R*).

4

Type P DA and press RETURN.
The system prints the date, time, transaction numbers, sequence number, and version number,
followed by the command prompt (R*).

5

Type LOG MESS...Testing Okidata Printer
The printer should repeat the typed message plus the date and time.

6

Type EX and press RETURN.
The system prints Sign off, along with the day, date, and time. When command terminal and
logger are connected on the same port, the system goes into the monitor mode.

Modem

If modem is not supplied by GASBOY, it must be set up using the following parameters:

• Modem hangs up with on/off transmission of DTR
• Auto answer enabled
• Carrier detect present when connection is complete
• Jack select RJ41S RJ455
• Bell compatible with 103/212A modems
• Line error detect disabled
• Result code disabled

Note: This procedure verifies remote polling only. This is not a network test. Consult your

network representative for network testing.

1

Turn on the site modem and the modem/data terminal device from which the call will
originate.

2

Set communication program to proper baud rate (9600 default), N, 8, 1
(refer to the operator's manual that comes with the modem).