Optional features – Gasboy CFN Series Site Controller III Start-up User Manual
Page 100

Start-up Commands
Optional Features
Page 94 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008
Optional Features
To enable the optional features, proceed as follows:
1
If you use the allocation feature, type REM AL;A to initialize the totalizer file (
This erases the entire file and frees all cards from allocation.
Figure 13-38: Example of REM AL;A Command
P* REM AL;A
P*
2
Type LO AL;C to assign allocation amounts to allocation numbers (
).
Note: If the number in AMOUNT? is preceded by a dollar sign, the value is in dollars ($250
allocation in the first example). If the AMOUNT? is typed alone, the value is assumed to
be gallons (120 gallons in the second example).
Figure 13-39: Example of LO AL;C Command with Prompts
P* LO AL;C
Allocation no.? 123
Amount? $250.00
Allocation no.? 300-310
Amount? 120.00
Allocation no.?
P*
3
If you use the MPG option, type LO V;IC to clear the vehicle file and load vehicles and
odometer readings (
).
Figure 13-40: Example of LO V;IC Command with Prompts
P* LO V;IC
Vehicle number? 100
Odometer reading? 22954
Vehicle number?
P*