beautypg.com

Optional features – Gasboy CFN Series Site Controller III Start-up User Manual

Page 100

background image

Start-up Commands

Optional Features

Page 94 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008

Optional Features

To enable the optional features, proceed as follows:

1

If you use the allocation feature, type REM AL;A to initialize the totalizer file (

Figure 13-38

).

This erases the entire file and frees all cards from allocation.

Figure 13-38: Example of REM AL;A Command

P* REM AL;A

P*

2

Type LO AL;C to assign allocation amounts to allocation numbers (

Figure 13-39

).

Note: If the number in AMOUNT? is preceded by a dollar sign, the value is in dollars ($250

allocation in the first example). If the AMOUNT? is typed alone, the value is assumed to
be gallons (120 gallons in the second example).

Figure 13-39: Example of LO AL;C Command with Prompts

P* LO AL;C

Allocation no.? 123

Amount? $250.00

Allocation no.? 300-310

Amount? 120.00

Allocation no.?

P*

3

If you use the MPG option, type LO V;IC to clear the vehicle file and load vehicles and
odometer readings (

Figure 13-40

).

Figure 13-40: Example of LO V;IC Command with Prompts

P* LO V;IC

Vehicle number? 100

Odometer reading? 22954

Vehicle number?

P*

This manual is related to the following products: