Release, applications, and system data, Standalone profit point setup – Gasboy CFN Series Site Controller III Start-up User Manual
Page 104

Start-up Commands
Release, Applications, and System Data
Page 98 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008
Release, Applications, and System Data
Note: Before trying this procedure, refer to MDE-4762 Site Controller III Manager’s Manual
for Windows XP Embedded for the latest backup routines and commands.
1
Obtain several (minimum 4) blank formatted (high capacity) diskettes.
2
Type HARDBACK and press ENTER.
(You must run SYSBACK before running HARDBACK).
3
Follow the prompts to insert and label diskettes.
4
Store backups in a safe place.
Standalone Profit Point Setup
Since a demo MASTER.PLU file exists on the Profit Point, you must delete or rename this file
before loading department and item information.
1
To do this, access the Main Menu by turning the Manager’s key to MGR position, sign on (if
required), press SPEC FUNC, 0 and ENTER.
The Main Menu displays.
2
Press 0 and ENTER.
The DOS prompt (C:\POS>) displays.
3
To delete the MASTER.PLU file, type DEL MASTER.PLU and ENTER.
~ OR ~
To rename the file, type REN MASTER.PLU and the new name of the file and press ENTER.
4
Type menu 2 and press ENTER.
5
Press 0 and ENTER.
The Main Menu displays.
To return to POS mode, select 1 on the Main Menu and press ENTER.
6
Execute special function 37.
It may be necessary to sign on as a user with a higher permission level.
This command copies the site configuration (pumps, products, prices, and so on) and
department information (price, name, floor and ceiling prices, price override, and so on) to the
Profit Point's MASTER.PLU file. Once this is done, you will have to load additional
information into the Profit Point. Use the forms from the
on
to help
you define your data and refer to MDE-4356 Profit Point Reference Manual for detailed
instructions.