Dip switches – Gasboy CFN Series Site Controller III Start-up User Manual
Page 53

MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008
Page 47
ICR
Jumpers and Switch Settings
ICR
DIP Switches
The ICR has an S2 bank of 10 Dual Inline Package (DIP) switches. Switches 1 through 6
provide functional settings; switches 7 through 10 are address settings. The settings and
functions are shown in the following tables.
ICR Software
Switch
Function
S2-1
No function
S2-2
DPT
Open = enables decimal point on the keypad.
Closed = the decimal point acts as a CLEAR key.
S2-3
DIS
Open = two lines of display are displayed.
Closed = only one line of display is displayed.
S2-4
INSRT
Open = insertion magnetic card reader.
Closed = swipe magnetic card reader or optical reader.
S2-5
GATE
Open = ICR.
Closed = gate controller.
S2-6
OPT
Open = optical reader.
Closed = magnetic card reader.
An address must be set up to identify the ICR. This address is a unique identifier for when
multiple ICRs are connected on the same RS-485 line. Up to 16 units can be used on the same
line (there are 16 addresses). Addressing should start at 1 and continue sequentially through
16. The physical wiring order does not have to correspond with the address order (the first unit
on the RS-485 line does not have to be address 1). The chart below gives the switch setting for
the address selections.
Note: The standalone receipt printer (when used) is addressed as an ICR; ensure that you use
an address different from any ICR.
Address
S2-7
S2-8
S2-9
S2-10
Address
S2-7
S2-8
S2-9
S2-10
ADDR4
ADDR3
ADDR2
ADDR1
ADDR4
ADDR3
ADDR2
ADDR1
1
Closed
Closed
Closed
Closed
9
Open
Closed
Closed
Closed
2
Closed
Closed
Closed
Open
10
Open
Closed
Closed
Open
3
Closed
Closed
Open
Closed
11
Open
Closed
Open
Closed
4
Closed
Closed
Open
Open
12
Open
Closed
Open
Open
5
Closed
Open
Closed
Closed
13
Open
Open
Closed
Closed
6
Closed
Open
Closed
Open
14
Open
Open
Closed
Open
7
Closed
Open
Open
Closed
15
Open
Open
Open
Closed
8
Closed
Open
Open
Open
16
Open
Open
Open
Open
An S3 switch enables the diagnostic mode of the ICR. Diagnostic mode is enabled when the
switch is in the down position.
Switch
Function
S3
Up = normal; Down = test mode