MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008

Page 43

PCU

Jumpers and Switch Settings

8

Pulser Type: Verify if switch SB-5 is set for the proper pulser type, single or dual. Settings are
shown below.

The pulser select switch is set for either single or dual pulsers. If dual pulsers are selected, all
pumps on the PCU must have dual pulsers.
Note: The dual pulser type feature requires a Profit Point Console (PPC) Motherboard III

and a PPC I/O PCB III. Both are not yet available; therefore, this switch should be
closed.

Pulser Type

SB-5

DUAL

Single

Closed

Dual

Open

9

Delay Time: The delay time is the period between activation of the SUB and the activation of
the slow flow and fast flow valves. The delay time switches are set to accommodate a variety
of leak detectors used in SUB applications. The time should be set according to the type of
leak detector installed on the SUB to allow a normal leak test for each transaction. If different
leak detectors are used on each pump, set the switches to the longest delay time required. Set
the delay time to zero seconds for SUCs.
Note: The leak detect delay time feature requires a PPC Motherboard III. The PPC

Motherboard III is not yet available; therefore, these switches should be closed.

4

Open

Open

Closed

Closed

5

Closed

Closed

Open

Closed

6

Open

Closed

Open

Closed

7

Closed

Open

Open

Closed

8

Open

Open

Open

Closed

9

Closed

Closed

Closed

Open

10

Open

Closed

Closed

Open

11

Closed

Open

Closed

Open

12

Open

Open

Closed

Open

13

Closed

Closed

Open

Open

14

Open

Closed

Open

Open

15

Closed

Open

Open

Open

16

Open

Open

Open

Open

Address

SB-1

SB-2

SB-3

SB-4

ADDR1

ADDR2

ADDR3

ADDR4