Start-up Commands

Diagnostics and History

Page 96 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008

Diagnostics and History

To obtain the diagnostics and history information, proceed as follows:

1

Type RE DI;I to set the diagnostic error totals to zero (

Figure 13-42

).

Figure 13-42: Example of RE DI;I Command

P* RE DI;I

P*

2

Type E HI;I to enable history recording (

Figure 13-43

).

This is initialized when you receive the system, but it will contain every command you just
performed. Enabling it here lets you start-up the history with a clean slate.

Figure 13-43: Example of E HI;I Command

P* E HI;I

P*

3

Type RUN;I to start the site (

Figure 13-44

).

Figure 13-44: Example of RUN;I Command with Prompt

P* RUN;I

Verify (y/n)? y

P*

4

Type P DI (

Figure 13-45

).

This prints diagnostics so you can verify if the system is okay.

Figure 13-45: Example of P DI Command

P* P DI

P*