Start-up Commands
Diagnostics and History
Page 96 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008
Diagnostics and History
To obtain the diagnostics and history information, proceed as follows:
1
Type RE DI;I to set the diagnostic error totals to zero (
).
Figure 13-42: Example of RE DI;I Command
P* RE DI;I
P*
2
Type E HI;I to enable history recording (
).
This is initialized when you receive the system, but it will contain every command you just
performed. Enabling it here lets you start-up the history with a clean slate.
Figure 13-43: Example of E HI;I Command
P* E HI;I
P*
3
Type RUN;I to start the site (
Figure 13-44: Example of RUN;I Command with Prompt
P* RUN;I
Verify (y/n)? y
P*
4
Type P DI (
This prints diagnostics so you can verify if the system is okay.
Figure 13-45: Example of P DI Command
P* P DI
P*