Component Power-up and Configuration

Okidata® Printer/Logger

Page 60 MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008

Printer Configuration Submenu

The printer configuration submenu allows you to select a forms or invoice printer and specify
the port (LPT1 or LPT2) to which it is connected. The receipt printer, if present, is still
connected to LPT1 and prints receipts regardless of this configuration. Refer to MDE-4356
Profit Point Reference Manual for details.

Scanner Configuration

When purchased from Gasboy, the scanner should be set up at the factory. If it is not, it is
programmed by scanning bar codes supplied with the scanner. A configuration instruction
sheet, including a list of required bar codes, is packed with the scanner. Refer to MDE-4356
Profit Point Reference Manual for scanner port parameters.

Okidata

®

Printer/Logger

The following printer switch settings are applicable for the Okidata 184 printer when
connected to a GASBOY CFN Fuel Management System. This document is not intended to be
a complete reference for the printer. Consult the documentation that came with the printer.

To prepare the Okidata 184 printer for operation with your GASBOY Fuel Management
System, perform the following steps. Install and complete the setup of the printer as specified
in the manufacturer's setup instructions. Then set up the switches as follows:

SW1-1

ON

Parity: Odd

SW1-2

ON

Parity: Without

SW1-3

ON

Data bits: 8

SW1-4

OFF

Protocol: XON/XOFF

SW1-5

ON

Test select: Circuit

SW1-6

ON

Mode select: Print

SW1-7

ON

Busy line selection: DTR - Pin 20

SW1-8

ON

Busy line selection: DTR - Pin 20

SW2

Baud Rate

SW2-1

SW2-2

SW3-3

9600

OFF

ON

ON

2400

OFF

OFF

ON

1200

ON

ON

OFF

300

ON

OFF

OFF

Note: Any change to the baud rate must also be changed on the Link Terminal