beautypg.com

Before using fuel point – Gasboy CFN Series Site Controller III Start-up User Manual

Page 81

background image

MDE-4793A CFN Series Site Controller III Start-up Manual for CFN III Versions 3.5 and above · November 2008

Page 75

Profit Point or SC III/POS WS - Prepay Pump Activation Test (Optional when using Dual-stage Solenoid Valves) Pump/

4

Press PAYABLE until sale is selected in pull down menu.

5

Pay off sale (Press CASH, enter amount, ENTER).
Drawer will open. Close drawer.

6

Verify if the quantity displayed on the pump 1 register matches the quantity recorded on the
logger printout (cash price, price level 1 or level 0 if no level 1 is used).

7

Repeat steps

1

through

6

for all hose outlets.

Profit Point or SC III/POS WS - Prepay Pump Activation
Test (Optional when using Dual-stage Solenoid Valves)

To perform the Profit Point or SC III/POS WS - Prepay Pump Activation Test, proceed as
follows:

1

Select pump 1 by pushing the Pump 1 key on the Profit Point.

2

Prepay the sale (PREPAY, 1 0 0, ENTER, START).
Drawer opens. Close drawer.

3

Use the pump handle to turn on pump 1 and squeeze the nozzle.
Pump product until it stops. Pump 1 will dispense product in fast flow until the slow cutoff is
reached, then the pump will dispense slowly until cutoff.

4

Verify if the total sale and gallon amount displayed on the pump 1 register matches the volume
and amounts you pre-selected on the Profit Point. Verify if the printout on the log printer
matches these totals.

5

Repeat steps

1

through

4

for all hose outlets.

Before Using Fuel Point

Before using Fuel Point, verify the following.

• Vehicle Modules (VM) are installed in accordance with C35699 Fuel Point VM

Installation Manual.

• VMs are programmed as explained in MDE-4524 VM Programming Manual.
• The necessary SC configurations have been made to FUELPT.BIN and SYS_PAR.BIN,

using MDE-4314 CFN III Configuration Manual for Windows NT

®

. The configurations to

FUELPT.BIN must match the factory-configuration of the VM programmer. If you do not
know how your programmer is configured, call GASBOY Technical Services for
assistance.

This manual is related to the following products: