Appendix

C -

Redundancy

C-11

MN/22156, rev 12

VMS Redundancy

NOC, for example.

Click the Traps tab, shown in figure C-6, to display the existing SNMP

Manager traps. Use the Insert, Modify, and Remove buttons to add new

traps and modify or remove existing traps. Refer to Appendix D, “SNMP

Traps”, for detailed information on the SNMP Manager.

Figure C-6 VMS Server Properties, Traps Tab

6. When finished, click the OK button to save the server properties settings.

7. Repeat steps 2 through 6 for each VMS server in the redundancy group.

8. Place the VMS server with the highest redundancy priority into the active

state:

Connect the console to the server with the highest priority and select the

Activate command from the VMS Server drop-down menu.