Network Manager Configuration
To prevent a routing loop from occurring, do NOT add the subnet for the
remote site that owns this list.
6. When all desired subnets have been added, click OK to enter this list in the
Distribution Lists table.
7. Repeat steps 1 through 6 to define additional lists.
8. A list entry is enabled/disabled with the use of the check box.
9. Click on Apply to save these list table entries.
Switching Function Verification
Once the InBand management configuration for a Remote is completed, the
VMS switching functions will become active. At this point, manual switch
commands can be used to verify that the switching function is operable. The
following procedure will demonstrate a manual application switch operation
from STDMA mode to SCPC mode utilizing a bandwidth slot assigned by the
VMS from one of the pools that were created in the RF Manager configuration
procedure.
1.
Right-click on an InBanded Remote site in the Network Manager and select
Application Sessions from the drop-down menu (figure 3-87).
Figure 3-87 Application Sessions menu command