beautypg.com

Custom circuit configuration, Custom circuit configuration -26 – Comtech EF Data VMS v3.12.x Vipersat User Manual

Page 382

background image

Switching Out-of-Band Modems

MN/22156, rev 12

7-26

VMS User Guide

Figure 7-22 Commit Page, Half Duplex Broadcast

Custom Circuit Configuration

While Full Duplex point-to-point and Half Duplex broadcast should cover most

Out-of-Band scenarios, the Custom circuit type addresses special cases.

Although it can be used to configure typical point-to-point and broadcast

circuits, it primarily provides a means for creating atypical circuit types. Illus-

trated below is an example of how to build a full duplex point-to-point

combined with a half duplex broadcast in a single circuit.
The Custom circuit type utilizes managed devices and unmanaged/assigned

devices, rather than units. Thus, the selection process requires navigating down

to the device level to select a modulator and demodulator(s) for each channel

that will belong to this circuit.

1.

Right-click on the site icon that will be utilizing the circuit and select Create

OOB Circuit from the drop-down menu to open the Circuit Creation

Wizard. The Hub site is used in this example.
The Circuit Identification dialog will appear, as shown in figure 7-23.

2. Select the Custom radio button in the Type box.

3. Enter a Label and a Description for this circuit.