SNMP Modem Manager

Figure 7-2 SNMP Modem Manager Properties

There are three settable parameters in the SNMP Modem Manager

Properties—the Status Poll Interval, the SNMP Timeout, and the SNMP

Attempts. They are described below.

Status Poll Interval – The time, in minutes, between full status polls

sent by the VMS to monitor the health (alarm states) and parameter

settings for the modems.

SNMP Timeout – The amount of time, in seconds, before the VMS

will retry a poll or SNMP command after no reply.

SNMP Attempts – The total number of attempts the VMS will make to

communicate with a modem before reaching a fail state, at which point

the VMS will set the modem status indicator to gray (unknown).

Configure SNMP Modem

The following procedure demonstrates using the SNMP Modem Manager to

configure a CDM-600L modem, as an example.

1.

Right-click on the SNMP Modem Manager and select the Declare Modem

command from the drop-down menu.
The New SNMP Modem dialog will open, figure 7-3.

2. From the Unit Type pull-down menu, select the model that corresponds to

this modem. In this example, the CDM600L modem is selected.
Proper selection is important, as this will identify the correct SNMP MIB to

be used for communications with the modem.