Comtech EF Data CTOG-250 User Manual
Page 43

CTOG-250 Comtech Traffic Optimization Gateway
Revision 1
Installation
MN-CTOG250
2–3
• Due to the location of its side-configured cooling vents and exhaust fans, the
CDM-800 Gateway Router CANNOT have slide rails mounted to the sides of its
chassis – airflow must not be impeded. Comtech EF Data therefore recommends
that an alternate method of support is provided within the rack, such as
standard rack shelves or the optional Rear-Mounting Support Bracket Kits. If
there is any doubt, contact Comtech EF Data Product Support.
Feature
Description
1
Custom Rack Enclosure
2
CTOG-250 Comtech Traffic Optimization
Gateway
3
CDM-800 Gateway Router
4
Standard Rack Shelving
5
Rack Enclosure Threaded Front Mounting
Rail (typical)
6
Unit Front Panel
7
User-supplied Screws
Figure 2-2. Installing into a Rack Enclosure
Mount the CTOG-250 and the CDM-800 Gateway Router into their assigned positions in the rack
enclosure. Use, as required:
• Standard rack shelving;