beautypg.com

2 web server interface – operational features, 1 virtual front panel – Comtech EF Data CTOG-250 User Manual

Page 108

background image

CTOG-250 Comtech Traffic Optimization Gateway

Revision 1

Ethernet-based Remote Product Management

MN-CTOG250

7–6

7.4.2 Web Server Interface – Operational Features

7.4.2.1 Virtual Front Panel

The CTOG-250 Web Server Interface features a read-only Virtual Front Panel (VFP) at the top of

every page. Here, CTOG-250 functionality is combined with CDM-800 front panel real-time LED

operation. These virtual LEDs provide ‘heads-up’ operational status indicators that react to any

changes made to unit operation, and convey operational states as follows:

LED

Condition

UNIT STATUS

Green

No Unit Faults or Alarms.

Amber

No Unit Faults, but an Alarm exists.

Red

A Unit Fault exists (Example: PSU fault).

STORED EVENT

Amber

There is a Stored Event in the log, which can be viewed from the Web

Server Interface or retrieved via the SNMP interface.

Off

There are no Stored Events.

ONLINE

Green

The Unit is On Line, and carrying traffic.

Off

The Unit is Off Line (standby – forced by externally connected 1:1 or 1:N

Redundancy System).

TEST MODE

Amber

A Test Mode is selected (Example: CW).

Off

There is no Test Mode currently selected.

TRANSMITTER ON

Green

The Transmitter Carrier is On.

Off

The Transmitter Carrier is Off.

Tx TRAFFIC

Green (solid)

No Tx Traffic Faults, no packets.

Green (blinking)

No Tx Traffic Faults, blinks when a packet is being transmitted to the

satellite link from this unit.

Off

A Tx Traffic Fault exists.

LAN-1 and LAN-2

LINK/ACTIVITY

Green (solid)

LAN Traffic Ethernet is connected, but no traffic exists.

Green (blinking)

LAN Ethernet activity detected.

Off

LAN Traffic Ethernet is not connected.

CDM-800 COMM’S

Green (solid)

CDM-800 connectivity detected.

Off

CDM-800 is not connected.

WAN LINK/ACTIVITY

Green (solid)

WAN Traffic Ethernet is connected, but no traffic exists.

Green (blinking)

WAN Ethernet activity detected.

Off

WAN Traffic Ethernet is not connected.

EXPNET-1

LINK/ACTIVITY

(EXPNET-2 IS NON-

FUNCTIONING)

Green (solid)

Expansion Traffic Ethernet is connected, but no traffic exists.

Green (blinking)

Expansion Traffic Ethernet activity detected.

Off

Expansion Traffic Ethernet is not connected.