beautypg.com

AMETEK i Series User Manual

Page 67

background image

User Manual

i Series / iX Series

53

4.2.6 TRANSIENTS Menu

Figure 4-11: TRANSIENTS menu

The transient menu provides access to the transient list data. Both the i and the iX Series have a
transient list of up to 32 data points. This is represented by 32 transient step numbers from 1
through 32. From the Transient menu, the desired transient step type can be selected. Based on
the user‟s choice, the relevant transient type sub menu will be shown. The START/EDIT
SEQUENCE sub menu allows the user to review and change any transient step or execute the
transient list. When executing a transient list, transient steps are executed in a ascending
numerical order. Steps that are not defined are skipped.

The following entries can be found in the TRANSIENTS menu:

Entry

Description

VOLT SURGE/SAG

Voltage surges and sags are temporary changes in amplitude.
The output voltage will change from its present value to a user
specified value for a specified duration. (Sag if the value is
lower, surge if the value is higher.) After this period has expired,
the output voltage returns to a user specified end value. This
value may or may not be the same as the value present prior to
the start of the sag or surge.

VOLT SWEEP/STEP

Voltage sweeps cause the output voltage to change from the
present value to a user specified end value at a specified rate of
change. A voltage step on the other hand is an instantaneous
change in output voltage. The new value will be held for the
duration period specified by the user. The final output voltage
value of a sweep and a step transient step should be different
than the value at the start of the transient step or no change in
output value will occur.

FREQ SWEEP/STEP

This transient type is similar to a voltage sweep/step except it
affects the frequency. Refer to the previous paragraph.

VOLT/FREQ SWEEP/STEP

This transient type combines the previous two types into a single
step. The effect is that of changing the output voltage and
frequency simultaneously.

Note: While this transient is programmed as a single transient
step, two list entries are required to store this information. As
such, every VOLT/FREQ SWEEP/STEP used will consume two
list entries at a time.

START/VIEW SEQUENCE

This entry allows the user to switch to the transient execution
menu. This menu provides a list of all available transient list
steps and their sequence numbers. From this menu, transient
list execution can be started.

The same menu can be used to view or edit any available
transient list step or erase a step using the backspace key.

This manual is related to the following products: