beautypg.com

AMETEK i Series User Manual

Page 326

background image

User Manual

312

i Series / iX Series

#

Test

No.

Subject

Test Limits

DO160 Ref.

Comments

Test File

29

6.2.11

Table 1.1 - N = 11

Run transient at 360Hz.

C6P0_APP1TransientsB_N11_36
0

30

6.2.1

Appendix 1: Figure 1.B

Table 1.1 - N = 1

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N1_800

31

6.2.2

Appendix 1: Figure 1.B

Table 1.1 - N = 2

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N2_800

32

6.2.3

Appendix 1: Figure 1.B

Table 1.1 - N = 3

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N3_800

33

6.2.4

Appendix 1: Figure 1.B

Table 1.1 - N = 4

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N4_800

34

6.2.5

Appendix 1: Figure 1.B

Table 1.1 - N = 5

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N5_800

35

6.2.6

Appendix 1: Figure 1.B

Table 1.1 - N = 6

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N6_800

36

6.2.7

Appendix 1: Figure 1.B

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N7_800

37

6.2.8

Appendix 1: Figure 1.B

Table 1.1 - N = 8

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N8_800

38

6.2.9

Appendix 1: Figure 1.B

Table 1.1 - N = 9

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N9_800

39

6.2.10

Appendix 1: Figure 1.B

Table 1.1 - N = 10

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N10_80
0

40

6.2.11

Appendix 1: Figure 1.B

Table 1.1 - N = 11

Repeat transient at 800Hz.

C6P0_APP1TransientsB_N11_80
0

41

6.3.1

Appendix 1: Table 2

Table 2 - N = I

Run transient at 360Hz and 800Hz.

C6P0_APP1TransientsT2_I

42

6.3.1

Appendix 1: Table 2

Table 2 - N = II

Run transient at 360Hz and 800Hz.

C6P0_APP1TransientsT2_II

43

6.3.1

Appendix 1: Table 2

Table 2 - N = III

Run transient at 360Hz and 800Hz.

C6P0_APP1TransientsT2_III

44

6.3.1

Appendix 1: Table 2

Table 2 - N = IV

Run transient at 360Hz and 800Hz.

C6P0_APP1TransientsT2_IV

45

6.3.1

Appendix 1: Table 2

Table 2 - N = V

Run transient at 360Hz and 800Hz.

C6P0_APP1TransientsT2_V

46

6.3.1

Appendix 1: Table 2

Table 2 - N = VI

Run transient at 360Hz and 800Hz.

C6P0_APP1TransientsT2_VI

47

7

Voltage Modulation

Fig 4-A

16.5.1.2

Replace DO160 Fig 16.1 with Fig 4-A

A7P0_VMOD

48

8

Frequency variations

49

8.1

Normal Frequency variations

Fig 5, limits 1 and 4

16.5.1.6

Slew at 100Hz/sec

C8P0_NORMFREQVARS

50

8.2

Emergency Frequency variations

Fig 5, limits 1 and 4

16.5.1.6

Slew at 500Hz/sec

C8P0_EMERFREQVARS

51

9

Frequency modulation

Fig 6

16.5.3.1

C9P0_FMOD

52

10

Distorted Voltage

53

10.1

Distorted Voltage 10% - Normal

Par 2.4.2.6.2

n/a

Test condition 2 Normal

C10P0_VDIST10

54

10.2

Distorted Voltage 15% - Emergency

Par 2.4.2.6.2

n/a

Test condition 2 Emergency

C10P0_VDIST15

55

10.3

Distorted Voltage 25% - Emergency

Par 2.4.2.6.2

n/a

Test condition 3 Emergency

C10P0_VDIST25