AMETEK i Series User Manual
Page 326

User Manual
312
i Series / iX Series
#
Test
No.
Subject
Test Limits
DO160 Ref.
Comments
Test File
29
6.2.11
Table 1.1 - N = 11
Run transient at 360Hz.
C6P0_APP1TransientsB_N11_36
0
30
6.2.1
Appendix 1: Figure 1.B
Table 1.1 - N = 1
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N1_800
31
6.2.2
Appendix 1: Figure 1.B
Table 1.1 - N = 2
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N2_800
32
6.2.3
Appendix 1: Figure 1.B
Table 1.1 - N = 3
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N3_800
33
6.2.4
Appendix 1: Figure 1.B
Table 1.1 - N = 4
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N4_800
34
6.2.5
Appendix 1: Figure 1.B
Table 1.1 - N = 5
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N5_800
35
6.2.6
Appendix 1: Figure 1.B
Table 1.1 - N = 6
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N6_800
36
6.2.7
Appendix 1: Figure 1.B
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N7_800
37
6.2.8
Appendix 1: Figure 1.B
Table 1.1 - N = 8
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N8_800
38
6.2.9
Appendix 1: Figure 1.B
Table 1.1 - N = 9
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N9_800
39
6.2.10
Appendix 1: Figure 1.B
Table 1.1 - N = 10
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N10_80
0
40
6.2.11
Appendix 1: Figure 1.B
Table 1.1 - N = 11
Repeat transient at 800Hz.
C6P0_APP1TransientsB_N11_80
0
41
6.3.1
Appendix 1: Table 2
Table 2 - N = I
Run transient at 360Hz and 800Hz.
C6P0_APP1TransientsT2_I
42
6.3.1
Appendix 1: Table 2
Table 2 - N = II
Run transient at 360Hz and 800Hz.
C6P0_APP1TransientsT2_II
43
6.3.1
Appendix 1: Table 2
Table 2 - N = III
Run transient at 360Hz and 800Hz.
C6P0_APP1TransientsT2_III
44
6.3.1
Appendix 1: Table 2
Table 2 - N = IV
Run transient at 360Hz and 800Hz.
C6P0_APP1TransientsT2_IV
45
6.3.1
Appendix 1: Table 2
Table 2 - N = V
Run transient at 360Hz and 800Hz.
C6P0_APP1TransientsT2_V
46
6.3.1
Appendix 1: Table 2
Table 2 - N = VI
Run transient at 360Hz and 800Hz.
C6P0_APP1TransientsT2_VI
47
7
Voltage Modulation
Fig 4-A
16.5.1.2
Replace DO160 Fig 16.1 with Fig 4-A
A7P0_VMOD
48
8
Frequency variations
49
8.1
Normal Frequency variations
Fig 5, limits 1 and 4
16.5.1.6
Slew at 100Hz/sec
C8P0_NORMFREQVARS
50
8.2
Emergency Frequency variations
Fig 5, limits 1 and 4
16.5.1.6
Slew at 500Hz/sec
C8P0_EMERFREQVARS
51
9
Frequency modulation
Fig 6
16.5.3.1
C9P0_FMOD
52
10
Distorted Voltage
53
10.1
Distorted Voltage 10% - Normal
Par 2.4.2.6.2
n/a
Test condition 2 Normal
C10P0_VDIST10
54
10.2
Distorted Voltage 15% - Emergency
Par 2.4.2.6.2
n/a
Test condition 2 Emergency
C10P0_VDIST15
55
10.3
Distorted Voltage 25% - Emergency
Par 2.4.2.6.2
n/a
Test condition 3 Emergency
C10P0_VDIST25