beautypg.com

AMETEK i Series User Manual

Page 293

background image

User Manual

i Series / iX Series

279

Test No. Section

Subject

Test Limits

Comment

File Ref.

1

One Phase Power Failures

0V for 7 seconds

Table TAC602-2 A-F

CTAC602-1

2

Two Phase Power Failures

0V for 30 mins

Table TAC602-2 G-J

CTAC602-2

TAC603

Phase Reversal

N/A to Rev C

Table LDC:

Test No. Section

Subject

Test Limits

Comment

File Ref.

LDC101

Load Measurements

28V DC

CLDC101

LDC102

Steady State Limits for Voltage

22V to 29V DC

Apply for 30 mins

CLDC102

LDC103

Voltage Distortion Spectrum

Requires Additional Equipment

LDC104

Total Ripple

Requires Additional Equipment

LDC105

Normal Voltage Transients

18V to 50V DC

1

Overvoltage Transients

Peak Voltage 50V DC

Table LDC105-3 AA-JJ

CLDC105-1

2

Undervoltage Transients

Low Voltage 18V DC

Table LDC105-3 KK-PP

CLDC105-2

3

Combined Transients

18V to 50V DC

Table LDC105-3 QQ-RR

CLDC105-3

4

Repetitive Normal Voltage Transient Test

18V to 45V DC

Repeat transient for 30 mins

CLDC105-4

LDC201

Power Interrupt

0V for 50 msec

Table LDC201-2 A-L

CLDC201

LDC301

Abnormal Steady State Limits for Voltage

20V to 31.5V DC

Apply each test for 30 mins

CLDC301

LDC302

Abnormal Voltage Transients

7V to 50V DC

1

Overvoltage Transients

Peak Voltage 50V DC

Table LDC302-3 AA-FF

CLDC302-1

2

Undervoltage Transients

Low Voltage 7V DC

Table LDC302-3 GG-LL

CLDC302-2

3

Combined Transients

7V to 50V DC

Table LDC302-3 MM-NN

CLDC302-3

LDC401

Emergency Limits for Voltage

16V to 30V DC

Apply each test for 30 mins

CLDC401

LDC501

Starting Voltage Transients

16V to 30V DC

Table LDC501-2 A

CLDC501

LDC601

Power Failure

0V for 7 seconds

Table LDC601-2 A-D

CLDC601

LDC602

Polarity Reversal

N/A to Rev B

Table HDC:

Test No. Section

Subject

Test Limits

Comment

File Ref.

HDC101

Load Measurements

270V DC

CHDC101

HDC102

Steady State Limits for Voltage

250V to 280V DC

Apply for 30 mins

CHDC102

HDC103

Voltage Distortion Spectrum

Requires Additional Equipment

HDC104

Total Ripple

Requires Additional Equipment

HDC105

Normal Voltage Transients

125V to 475V DC

1

Overvoltage Transients

Peak Voltage 475V DC

Table HDC105-1 A-J

CHDC105-1

2

Undervoltage Transients

Low Voltage 125V DC

Table HDC105-1 K-P

CHDC105-2

3

Combined Transients

125V to 475V DC

Table HDC105-1 Q-R

CHDC105-3

4

Repetitive Normal Voltage Transient Test

215V to 315V DC

Repeat transient for 30 mins

CHDC105-4

HDC201

Power Interrupt

0V for 50 msec

Table HDC201-2 A-L

CHDC201

HDC301

Abnormal Steady State Limits for Voltage

245V to 285V DC

Apply each test for 30 mins

CHDC301

HDC302

Abnormal Voltage Transients

65V to 475V DC

1

Overvoltage Transients

Peak Voltage 475V DC

Table HDC302-2 A-F

CHDC302-1

2

Undervoltage Transients

Low Voltage 65V DC

Table HDC302-2 G-L

CHDC302-2

This manual is related to the following products: