AMETEK i Series User Manual
Page 191

User Manual
i Series / iX Series
177
Table BDC14:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
16.6.1
Normal Operating Conditions (dc)
16.6.1.1b Voltage (Average Value dc)
11.0V to 15.2V
Apply for 30 mins each test
EBDC14_VAVG
16.6.1
Emergency Operating Conditions (dc)
16.6.1.1b(3) Voltage (Average Value dc)
9.0V
Apply for 30 mins each test
EBDC14_VAVGEMER
16.6.1
Normal Operating Conditions (dc)
16.6.1.2
1
Ripple Voltage (dc)
Vp-p = .8V, Freq = 200Hz
Figure 18-2
EBDC14_VRIP
16.6.1.3b Momentary Power Interruptions (dc)
Table 16-3
Equipment with Digital Circuits
EBDC14_PINTB
16.6.1.3c Momentary Power Interruptions (dc)
Other Equipment
EBDC14_PINTC
16.6.1.4 Normal Transients (dc)
16.6.1.4b - Normal Voltage Surge (dc)
23.5V to 8.5V
EBDC14_NVSUR
16.6.1.5 Engine Starting Under Voltage Operation (dc) 5V min
Slew for 35 sec
EBDC14_VENG
16.6.2
Abnormal Operating Conditions (dc)
16.6.2.1 Voltage Steady State (dc)
10.3V to 16.1V
Apply for 5 mins each test
EBDC14_VABN
16.6.2.2 Low Voltage Conditions (dc)
0V over 10 minutes
EBDC14_LVABN
16.6.2.3 Momentary Undervoltage (dc)
6V
Apply for 7 seconds each test
EBDC14_VUND
16.6.2.4 Abnormal Transients (ac)
16.6.2.4d - Abnormal Voltage Surge
30VDC
Figure 16-4 - apply at 10 sec
intervals
EBDC14_AVSUR
1
For more comprehensive DC Ripple tests, refer to section 9.1.2.10.