AMETEK i Series User Manual

Page 52

background image

User Manual

38

i Series / iX Series

OVER TEMPERATURE

The OVER TEMPERATURE LED indicates an overheating
problem inside the unit. This is an abnormal condition, which will
cause the unit to shut off. Check the air openings to make sure
they are not blocked.

HI RANGE

The HI RANGE LED is on when the high voltage output range
has been selected.

4.1.4 The Shuttle Knob

Counter
Clock
wise

Clock

wise

INCR

DECR

Figure 4-1: Shuttle Knob

The shuttle knob is located to the right of the LCD screen and is used to change setup
parameters. Note that it cannot be used to move the cursor position between menu fields. Use
the UP and DOWN arrow keys in the FUNCTION keypad for this.

The shuttle knob can operate in one of two distinct modes of operation:

MODE

DESCRIPTION

IMMEDIATE mode

Any time the ENTER key is pressed, the i/iX Series returns to its
normal mode of operation. In this mode, changes made with the
shuttle knob or the data entry keypad will take immediate effect.
The IMMEDIATE mode is useful for slewing output values such
as voltage and frequency and observing the effect on the load.

SET mode

When the SET key located in the FUNCTION keypad is
pressed, changes made with the shuttle to any output parameter
will not take effect until the ENTER key is pressed. In this mode,
any changes made to a setup menu will be blinking to indicate
the pending change condition. This mode allows changes to be
made to all output parameters and executing them all at once by
pressing the ENTER key.

4.1.5 FUNCTION Keypad

The function keypad provides access to all menus and measurement screens. The following
keys are located in the FUNCTION keypad: