AMETEK i Series User Manual
Page 20

User Manual
6
i Series / iX Series
Output Parameter
i Series
iX Series
Current Limit
programmable 0 to 100% of range for all ranges
Frequency Range:
16.00 - 81.91 Hz (0.01 Hz resolution)
81.0 - 500.0 Hz (0.1 Hz resolution)
Frequency Accuracy:
0.01% of programmed value
DC Offset Voltage:
Less than 20 mV with linear load.
Output Impedance
Range:
n/a
R
min
to 1000 m
L
min
to 1000 H
Resolution:
n/a
4 m
4 H
Accuracy:
n/a
2% F.S. at 796 H and 400 m
Output Noise:
(20 kHz to 1 MHz)
400 mVrms max, 135 V
range,
800 mVrms max, 270 V range
<250 mV rms (typ),
<500 mV rms (max)
Peak Rep AC Current:
3001i/iX
5001i/iX
9003i/iX
15003i/iX
110 A for 135 V range,
92 A for 270 V range
110 A for 135 V range,
100 A for 150 V range,
92 A for 270 V range,
83 A for 300 V range
10001i/iX
220 A for 135 V range,
184 A for 270 V range
220 A for 135 V range,
200 A for 150 V range,
184 A for 270 V range,
166 A for 300 V range
15001i/iX
330 A for 135 V range,
276 A for 270 V range
330 A for 135 V range,
300 A for 150 V range,
276 A for 270 V range,
249 A for 300 V range
Crest Factor:
Up to 5:1
Up to 5:1