AMETEK i Series User Manual
Page 17

User Manual
i Series / iX Series
3
2.1.2 Output
(ALL SPECIFICATIONS ARE FOR AC AND DC UNLESS NOTED OTHERWISE)
Output Parameter
i Series
iX Series
Modes:
AC, DC
AC, DC, AC+DC
Voltage:
Ranges (L-N):
AC Mode
Low:
0 - 135 VAC / High: 0 - 270 VAC
0 - 150 VAC / High: 0 - 300 VAC
DC Mode
Low:
0 - 135 VDC / High: 0 - 270 VDC
0 - 150 VDC / High: 0 - 300 VDC
AC+DC Mode
iX Models only.
AC:
Low: 0 - 150 V / High: 0 - 300 V
DC
Offset: Low 0 - 150 V / High; 0 - 250 V
Programming
Resolution:
AC Mode
0.1 V
DC Mode
0.1 V
AC+DC Mode
AC:
01. V
DC Offset:
0.01 V
< 0.5 V
0.1 V
0.6 - 25 V
1 V
> 25 V
Voltage Accuracy:
AC mode
0.5% of range, 16 to 400 Hz.
0.5% of range, 16 to 400 Hz.
DC mode
0.5% of range
0.5% of range
DC offset
(AC+DC mode)
5% of range ± 0.1 VDC.< 25VDC
5% of range ± 1 VDC.> 25VDC
Voltage Distortion
1
:
(linear load)
1% max THD at 50/60 Hz
2% max THD at 400 Hz
1% max THD at 50/60 Hz
2% max THD at 400 Hz
Load Regulation:
0.5% DC to 100 Hz
2.2% to 500 Hz (135 range)
0.6% to 500 Hz (270 range)
0.5% DC to 100 Hz.
2.2% to 500 Hz (135/150 range)
0.6% to 500 Hz (270/300 range)
Line Regulation:
0.1% for 10% input line
change
0.1% for 10% input line change
Power: (per phase, either range, at full scale voltage)
3001, 9003i/iX
5001, 15003i/iX
10001i/iX
3000 VA AC, 2100 W DC
5000 VA AC, 3500 W DC
10000 VA AC, 7000 W DC
3000 VA AC, 2100 W DC
5000 VA AC, 3500 W DC
10000 VA AC, 7000 W DC
1