beautypg.com

AMETEK i Series User Manual

Page 331

background image

User Manual

i Series / iX Series

317

9.10 WHM Option

9.10.1 General

This section describes the WHM option for the i / iX Series Power Source.

9.10.2 Specification

All specifications are the same as the standard i / iX Power Source specifications in addition to
the following specifications:

Watt-hour

0-6.000KW

0.01KWH + 0.1% <100Hz

0.02KWH +0.1% 100-500Hz

>6.000KW

Times three of the above specification

9.10.3 Local Operation

From the Menu screen 2, select the APPLICATIONS SETUP 2 screen. The screen will appear
as shown in Figure 9-70. Use the up and down key to position the cursor to the WH METER
field. Press the Enter Key.

Figure 9-70: Application Screen

The WATT-HOURS METER screen shown in Figure 9-71 has the following fields:

Figure 9-71 Watt-Hour Meter Screen

START: This field will activate the watt-hour measurements. Moving the shuttle clockwise when
the field is highlighted will activate the watt hour function and the field will change to STOP as
shown in Figure 9-72.

1. ETIME: This field will accumulate the time in hours, minutes and seconds.

2. WATT HR: This field will accumulate the watt-hour in KWH.

3. POWER: This field will report the instantaneous power in KW.

4. PK CURR: This field will report the peak current and will hold the maximum reading.

This manual is related to the following products: