beautypg.com

AMETEK i Series User Manual

Page 336

background image

User Manual

322

i Series / iX Series

Number

Message String

Cause

Remedy

error

-311

"Memory error"

Waveform memory
checksum error.

May be the result of incomplete user-
defined waveform download. Check
interface and try downloading
waveform again. Successful
download may clear this error
condition.

Alternatively, use TRAC:DEL ALL
command to clear waveform memory.

-314

"Save/recall memory
lost"

User setup register
contents lost

Store setup in same register again.

-315

"Configuration memory
lost"

Hardware
configuration settings
lost.

Contact CI service department at

[email protected]

to obtain

instructions on restoring configuration
data.

-330

"Self-test failed"

Internal error

Contact CI service department at

[email protected]

-350

"Queue overflow"

Message queue full.

Too many message. Read status
using SYST:ERR query until 0, "No
Error" is received indicating queue
empty.

-400

"Query error"

Unable to complete
query.

Check programming manual for
correct query format and parameters

-410

"Query
INTERRUPTED"

Query issued but
response not read.

Check application program for correct
flow. Response must be read after
each query to avoid this error.

-420

"Query
UNTERMINATED"

Query incomplete.

Check for terminator after query
command.

-430

"Query
DEADLOCKED"

Query cannot be
completed

Check application program for
multiple queries

-440

"Query
UNTERMINATED"

Query incomplete.

Check for terminator after query
command.

1

"Output volt fault"

Output voltage does
not match
programmed value.

Load exceeds current limit and unit is
in Constant Voltage (CV) mode of
operation. Reduce load or increase
CL setting
Output voltage is driven above
programmed voltage by external
influence (Load, voltage kickback,
etc.)

2

"Current limit fault"

Current limit
exceeded.

Load exceeds current limit and unit is
in Constant Voltage (CV) mode of
operation. Reduce load or increase
CL setting

3

"Temperature fault"

Temperature of heat
sink too high.

Reduce load. Ensure proper air flow
and exhaust clearance. Check fan(s)
for operation.

4

"External sync. error"

Could not sync to
external sync signal.

External sync signal missing,
disconnected or out of range.

5

"Initial memory lost"

Power on settings
could not be recalled.

Save power on settings again to
overwrite old content.

This manual is related to the following products: